The InfraCal 2 Ethanol Blend Analyzer for measuring percent ethanol in gasoline is the ideal solution where a quick, accurate, on-site measurement is required and a single, repetitive ethanol blend analysis is needed. The InfraCal 2 ATR-E is based on proven IR technology, and used by fuel terminals, laboratories and regulatory agencies worldwide. The compact, easy-to-use InfraCal 2 ATR-E has a measurement range of 0-20 & 70-98%% ethanol in gasoline and an accuracy of +/- 0.2%. These results are comparable to ASTM D4815.
Samples are applied to a zinc selenide attenuated total reflectance (ATR) sample plate and easily cleaned with a cloth & isopropyl alcohol. No solvents requiring special ventilation, expensive waste disposal or difficult to clean cells are needed. The analysis can be done by non-technical personnel with no formal training and is ideal for lab or field use. The InfraCal2 ATR-E has a touch screen display, data storage and transfer, a multi-language interface and password protected settings. The internal battery pack allows for portability and up to 12 hours continuous use, providing results in under a minute at a fuel loading rack, in a laboratory or at a pump in a fueling station.
- Measurement range: 0 - 20 & 70 - 98% ethanol in gasoline
- Instrument repeatability: +/- 0.2%
- Compares to ASTM D4815
|
Benefits |
Features |
|
Internal Data Storage |
Data storage including each measurement tagged with analyst, location and date/time information, and password protected instrument settings |
|
Export |
Directly to your PC via USB or a Flash Drive |
|
Touch Screen Display |
The touch screen display allows a simple set up for quick operation along with an easy calibration wizard. |
|
Internal Battery |
The internal battery pack allows for portability and up to 6 hours continuous use. |
| Multi-Language Interface |
English, Spanish, French, Arabic |
|
Password Protected Settings |
Calibration and data are password protected to avoid accidental deletion |
|
No need for Installation/Commissioning |
The InfraCal 2 is a portable analyzer, weighing less than 5 lbs. with a 6 in. square foot print, requiring no installation or commissioning, little to no routine maintenance or recalibration. |
|
Minimal Consumables |
The analysis requires little to no consumables making the cost-per-test minimal. |
Specifications
| Item | Specifications |
| Analytical Wavelength/Wave Number | 9.6 µm, 1045cm-1 |
| Power Requirements | 18 volts DC, 3.3 amps, internal battery pack |
| Power Supply | Universal AC/DC provided |
| Weight | 5.8 lb. (2.6 kg) with battery -7.0 lbs (3.2 kg) |
| Dimensions | |
| Suggested Operating Range | 5°C - 40°C |
| Measurement Range | 0 - 20 & 70 - 98% ethanol in gasoline |
| Analysis Time | Less than 30 seconds |
| Instrument Repeatability | 0 - 20%±0.2%, 20 - 98%±1% of ethanol in petrol concentration |
| Communication Port | USB, RS 232 |